앱 다운로드Get the app
Alpha

Alpha 에러코드Alpha error codes

60개 코드 · 1개 제품군60 codes · 1 categories

🔥보일러·온수기Boilers & Water Heaters 60

0A1점화 실패Ignition failure. (Pro Tec Plus)0A15플로우/리턴 센서 이상 — 센서가 잘못된 온도값을 표시Flow and return sensor anomaly detected; the sensor shows an incorrect temperature value0A18플로우/리턴 센서 이상 — 급격한 온도 변화 감지Flow and return sensor anomaly: sudden temperature change detected on the flow or return sensor0A2화염 감지 이상Flame detection fault. (Pro Tec Plus)0A21메인 PCB 이상Main PCB fault.0A3과열 서모스탯 락아웃(서모스탯·열퓨즈·수동복귀 서모스탯 관련)Overheat thermostat lock-out. Relating to thermostats, thermal fuse, or manual reset thermostat.0A30·0A31·0A43·0A440A30 플로우 센서 단락 / 0A31 플로우 센서 범위 초과 / 0A43 리턴 센서 단락 / 0A44 리턴 센서 범위 초과0A30 flow sensor short circuit / 0A31 flow sensor out of range / 0A43 return sensor short circuit / 0A44 return sensor out of range0A37(Protec 50)시스템 플로우 부족Insufficient system flow0A4공기압 스위치 이상Air pressure switch fault0A5팬 속도 이상Fan speed fault.0A7고 플루 온도High flue temperature fault.0A8화염 회로 이상Flame circuit fault0A80플로우/리턴 센서 배선 연결 오류(운전 수 분 뒤 발생 가능)Flow and return sensor connection fault0A9가스밸브 전기 오류Gas valve electrical error.0E13최대 리셋 도달Maximum number of resets reached. More than five reset attempts have been reached within 15 minutes.0E2화염 감지 이상Flame sensing fault0E25메인 PCB 이상(소프트웨어 오류)Main PCB fault0E32DHW 센서 단락DHW sensor short circuit0E33DHW 센서 범위 초과 — DHW 센서가 정상 동작범위 밖 온도를 읽음DHW sensor out of range. DHW sensor measures a temperature outside normal working range.0E34공급 전압 저하Low power supply voltage.0E37시스템 압력 부족Insufficient system pressure (Pro Tec Plus 70, 90, 115) or pressure and flow (Pro Tec Plus 50).0E45·0E460E45 플루 센서 단락 / 0E46 플루 센서 범위 초과0E45 flue sensor short circuit / 0E46 flue sensor out of range0E81플로우/리턴 센서 이상 — 센서 온도값 부정확Flow and return sensor anomaly detected; the sensor shows an incorrect temperature value0E98심플 캐스케이드 통신 오류('M to O' 연결·PCB 소프트웨어 확인)Simple cascade communication error0E99캐스케이드 통신 오류Simple cascade communication error.1점화 실패(화염 미검출)Ignition failure - flame not detected during ignition sequence.101차 시스템 저압Primary system pressure low - primary pressure switch has operated.12실린더 센서 이상(FlowSmart 한정)DHW inlet sensor fault - optional DHW inlet sensor resistance out of range.15내부 배선 오류Incorrect configuration - incorrect hydraulic configuration; inconsistency between the settings and signals received from the PCB.16팬 이상Fan fault - fan wiring fault or fan faulty.2과열 락아웃Overheat boiler lock out - overheat sensor has activated.20화염 감지 이상Flame sensing fault - false flame detection; flame detected but gas valve is not open.23난방 리턴 센서 이상Return sensor fault - return sensor resistance out of range.24제어판 버튼 걸림Control panel button fault - control panel button stuck in the on position.25과열 락아웃PCB fault - software error.271차 플로우 부족Primary circuit overheat - insufficient circulation in primary circuit causing overheating.29플루 센서 이상Flue sensor fault - flue sensor resistance out of range.3플루 서모스탯 고온High flue temperature - flue sensor intervention (flue temperature too high).31외부 컨트롤(Climatic) 통신 상실Loss of communication with external control (Alpha Climatic) - loss of connection between the boiler and Alpha Climatic control unit.37공급전압 저하Low supply voltage - insufficient supply voltage to operate boiler.38·43화염 정류(rectification) 상실Loss of flame rectification4가스밸브 전기연결 이상Gas valve electrical connection fault - gas valve wiring circuit fault detected.44안전 락아웃Safety lock out - the boiler has attempted to fire repeatedly for the maximum time limit. (Alpha InTec 40GS2)45과대 온도차(플로우/리턴)High delta-T - the boiler detects a sudden, unexpected increase in delta-T between the flow sensor and the system return sensor.46외부 센서 개입External sensor intervention - no continuity of external sensor circuit. (Alpha InTec 40GS2)47버너 출력 저하Reduced burner output - flue thermostat has sensed high flue gas temperature (110C) and reduced the burner output to prevent damage. If the temperature continues to rise the boiler will lock out and E03 will be displayed.5난방 플로우 센서 이상CH flow sensor fault - incorrect flow sensor resistance value.51Climatic RF 통신 이상Climatic RF communication fault - error between communication of the Climatic transmitter and boiler receiver.6DHW(온수) 센서 이상DHW sensor fault - DHW sensor resistance value is incorrect.60펌프 오류(고착/전기)Pump fault - the pump is stuck or there is an electrical pump fault.61펌프 내 공기(난방 플로우 제한)Air in the pump - restricted CH flow due to air or a circuit restriction.7굴뚝청소(chimney sweep) 기능 활성Chimney sweep function active70·75·76리턴/플로우 센서 배선교차·고장Return/flow sensor wiring crossed · failure711차 회로 온도 미상승 — 점화 후에도 1차 회로 온도가 오르지 않음No primary temperature increase detected: from ignition the boiler detects no temperature rise in the primary circuit.8최대 리셋 횟수 초과Max. number of resets - maximum number of resets reached (5).FE94디스플레이 PCB 이상Display PCB fault.FE95외부 플로우 센서 범위 초과 또는 단락External flow sensor out of range or short circuitFE96외부 센서 이상External sensor faultFE97보일러 PCB 구성 오류Boiler PCB configuration error. This may occur if the main PCB or display PCB is changed.SR서비스 리마인더Service reminder